Search scope:
排序: Display mode:
Dynamical Experiment Research on New Seismic Isolation Bearings with SMA Wires
Deng Zongcai,Sun Hongjun,Liu Chunguo,Niu Kun,Deng Hongliang
Strategic Study of CAE 2005, Volume 7, Issue 12, Pages 61-68
As the aim of improving the utilization ratio of SMAs in SMA-rubber seismic isolation bearings, severaldifferent SMA-rubber seismic isolation bearings were designed, and energy dissipation experiments wereisolation bearings including level displacement amplitude, level loading frequency and vertical loadResult showed that the new SMA-rubber seismic isolation bearings have better hysteresis and energy dissipationIt provided the base to optimize the SMA-rubber seismic isolation bearings.
Keywords: shape memory alloy seismic isolation bearings initial stiffness hysteresis energy dissipation equivalent
Innovative seismic retrofitting strategy of added stories isolation system
Min-Ho CHEY, J. Geoffrey CHASE, John B. MANDER, Athol J. CARR
Frontiers of Structural and Civil Engineering 2013, Volume 7, Issue 1, Pages 13-23 doi: 10.1007/s11709-013-0195-9
Keywords: added stories seismic isolation tuned mass damper parametric optimization statistical method
Weilian QU, Jianwei TU
Frontiers of Structural and Civil Engineering 2009, Volume 3, Issue 1, Pages 32-41 doi: 10.1007/s11709-009-0003-8
Keywords: Three-Gorges ship lift tower whipping effect magnetorheological (MR) intelligent isolation system neural
The development on seismic design and evaluation of CGNPC after Fukushima accident
Mao Qing,Wu Yingxi,Zhang Jian,Meng Ajun,Zhang Tao,Yang Chunju,Liu Fang
Strategic Study of CAE 2013, Volume 15, Issue 4, Pages 46-51
This paper introduced the seismic design requirements of nuclear powerplant, the seismic design situation of the unit in construction or in service, and the serious consequenceThen, it described in brief the measures on seismic analysis taken by countries who own nuclearFinally, this paper presented some steps for the new nuclear power plants at the seismic design and evaluationto enhance the seismic capacity of nuclear power plants through technical means.
Keywords: seismic design basis beyond design basis earthquake seismic margin assessment(SMA) seismic isolation
Rolling-element bearings in China: From ancient times to the 20th century
Lie SUN,Ang LI
Frontiers of Mechanical Engineering 2016, Volume 11, Issue 1, Pages 33-43 doi: 10.1007/s11465-016-0373-2
The development of rolling-element bearings in China has spanned a long period.several typical and important cases, the present article reconstructs the history of rolling-element bearingsin China by dividing it into four stages according to the various characteristics of the bearings.The first stage represents the origin of rolling bearings in China, which remains controversial becauseas replacement for traditional sliding bearings.
Keywords: bearing movement rolling-element bearing China early rolling bearings technology transfer
The earthquake threat and countermeasures to the safety of nuclear power plants
Zhou Fulin,Tan Ping,Liu Dewen
Strategic Study of CAE 2013, Volume 15, Issue 4, Pages 36-40
Nuclear energy is a carbon-free, clean and efficient energy. It is very important in the progress of human civilization and modern development of the world. However, there are still some problems such as nuclear leak and nuclear waste. In this paper, the world's nuclear energy utilization and nuclear power plant constructions are reviewed and plans are forecasted. The basic reason of previous nuclear power plant accidents in history is summarized. Taking 2011 Tohuku earthquake -fukushima nuclear power station accident as an example, threats to the nuclear power plant by earthquake are investigated and impacts on social, economic and ecological environment caused by nuclear power station accident are analyzed. This paper drew lessons from previous accidents and put forward a variety of countermeasures which are from both the technical and management aspects. This paper also put forward some suggestions. Security measures of the existing nuclear power plants should be assessed carefully. The long-term construction plan of the nuclear power plant should be improved. In addition, emergency management mechanism of the nuclear power plant can be enhanced in the future. The earthquake monitoring and earthquake early-warning system is critical and promoted to be established widely. The nuclear probability safety analysis (PSA) could be investigated in depth. The security education of the public should be continuously popularized and disaster drills be carried out regularly. International cooperation and communication are also advocated to be strengthened. All these measures can be significant in human process to explore nuclear energy correctly. We also appeal people all over the world to respect the nature, enjoy the nature, and to create and enjoy the new civilization of human beings.
Keywords: nuclear power plant seismic hazard tsunami location safety base isolation energy dissipation three-dimensionalbase isolation
Parametric study on the Multangular-Pyramid Concave Friction System (MPCFS) for seismic isolation
Wei XIONG, Shan-Jun ZHANG, Li-Zhong JIANG, Yao-Zhuang LI
Frontiers of Structural and Civil Engineering 2020, Volume 14, Issue 5, Pages 1152-1165 doi: 10.1007/s11709-020-0659-7
Keywords: seismic isolation variable frequency near-fault earthquake numerical study Multangular-Pyramid Concave
Application of Porous Aerostatic Bearings in Three-axis Table
Du Jinming
Strategic Study of CAE 2005, Volume 7, Issue 1, Pages 65-68
Aerostatic bearings have been applied widely in aviation, aerospace and precision electronics.Porous aerostatic bearings have higher load capacity, static stiffness and highed damping than otherrestricted bearings.aerostatic bearings.The results show the load capacity of porous aerostatic bearings is higher than orifice aerostatic bearings
Keywords: aerostatic bearings porous orifice restricted three-axis table
H∞ control in the frequency domain for a semi-active floor isolation system
Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA
Frontiers of Structural and Civil Engineering 2013, Volume 7, Issue 3, Pages 264-275 doi: 10.1007/s11709-013-0214-x
Keywords:
semi-active
floor isolation
Isolation and application of predatory
Ran Yu, Shiwen Zhang, Zhoukai Chen, Chuanyang Li
Frontiers of Environmental Science & Engineering 2017, Volume 11, Issue 1, doi: 10.1007/s11783-017-0900-3
Keywords: Bdellovibrio-and-like organisms (BALOs) Biolysis Activated sludge Dewaterability Predation
Novel polymorphic EST-based microsatellite marker isolation and characterization from
Manosh Kumar BISWAS,Peng CHEN,Mohamed Hamdy AMAR,Xiuxin DENG
Frontiers of Agricultural Science and Engineering 2015, Volume 2, Issue 1, Pages 60-65 doi: 10.15302/J-FASE-2015048
Keywords: microsatellite polymorphism Poncirus trifoliata
Min-Ho CHEY,J. Geoffrey CHASE,John B. MANDER,Athol J. CARR
Frontiers of Structural and Civil Engineering 2015, Volume 9, Issue 3, Pages 297-306 doi: 10.1007/s11709-015-0308-8
Keywords: smart building isolation story and structural energy-dissipation damage assessment
Li Aiqun: Research and Practice of High Performance Seismic Isolation Structure (2019-11-10)
李爱群(高级职称)
20 Jan 2021
Keywords: 城镇建设
Review of the damage mechanism in wind turbine gearbox bearings under rolling contact fatigue
Yun-Shuai SU, Shu-Rong YU, Shu-Xin LI, Yan-Ni HE
Frontiers of Mechanical Engineering 2019, Volume 14, Issue 4, Pages 434-441 doi: 10.1007/s11465-018-0474-1
Keywords: rolling contact fatigue (RCF) white etching area (WEA) white etching crack (WEC) adiabatic shear band (ASB)
Min-Ho CHEY,J. Geoffrey CHASE,John B. MANDER,Athol J. CARR
Frontiers of Structural and Civil Engineering 2015, Volume 9, Issue 3, Pages 286-296 doi: 10.1007/s11709-015-0307-9
Keywords: tuned mass damper smart building isolation resettable device non-linear statistical assessment
Title Author Date Type Operation
Dynamical Experiment Research on New Seismic Isolation Bearings with SMA Wires
Deng Zongcai,Sun Hongjun,Liu Chunguo,Niu Kun,Deng Hongliang
Journal Article
Innovative seismic retrofitting strategy of added stories isolation system
Min-Ho CHEY, J. Geoffrey CHASE, John B. MANDER, Athol J. CARR
Journal Article
Theoretical and experimental study on seismic response control on top of Three-Gorges ship lift towersusing magnetorheological intelligent isolation system and its key technique
Weilian QU, Jianwei TU
Journal Article
The development on seismic design and evaluation of CGNPC after Fukushima accident
Mao Qing,Wu Yingxi,Zhang Jian,Meng Ajun,Zhang Tao,Yang Chunju,Liu Fang
Journal Article
Rolling-element bearings in China: From ancient times to the 20th century
Lie SUN,Ang LI
Journal Article
The earthquake threat and countermeasures to the safety of nuclear power plants
Zhou Fulin,Tan Ping,Liu Dewen
Journal Article
Parametric study on the Multangular-Pyramid Concave Friction System (MPCFS) for seismic isolation
Wei XIONG, Shan-Jun ZHANG, Li-Zhong JIANG, Yao-Zhuang LI
Journal Article
H∞ control in the frequency domain for a semi-active floor isolation system
Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA
Journal Article
Isolation and application of predatory
Ran Yu, Shiwen Zhang, Zhoukai Chen, Chuanyang Li
Journal Article
Novel polymorphic EST-based microsatellite marker isolation and characterization from
Manosh Kumar BISWAS,Peng CHEN,Mohamed Hamdy AMAR,Xiuxin DENG
Journal Article
Aseismic smart building isolation systems under multi-level earthquake excitations: Part II, energy-dissipation
Min-Ho CHEY,J. Geoffrey CHASE,John B. MANDER,Athol J. CARR
Journal Article
Li Aiqun: Research and Practice of High Performance Seismic Isolation Structure (2019-11-10)
李爱群(高级职称)
20 Jan 2021
Conference Videos
Review of the damage mechanism in wind turbine gearbox bearings under rolling contact fatigue
Yun-Shuai SU, Shu-Rong YU, Shu-Xin LI, Yan-Ni HE
Journal Article